16 kanaler analog input station med RS485 interface (Intech 2400-A16-485-H)

> > Vare nr.: IN2400-A16-I16-485-H

16 stk. optisk isolerede analoge indgange

4 stk. digitale indgange

2 stk. relæ udgange

2 stk. 0/4-20mA udgange

Forsyning 85-265VAC

Understøtter Modbus RTU protokol

RS485 & RS422 kommunikation

Tilgængelighed

Ikke på lager Flere kan bestilles på restordre

DKK 8.970,00 ekskl. moms

Beskrivelse

  • Up to 16 Isolated Universal Analogue Inputs, with Plug In Terminals.
  • Each Input Individually Selected & Scaled.
  • 16 Bit Resolution.
  • Isolated Input for RTD, T/C, mA, mV, V & Pulse/Digital.
    • RTD: Pt100/Pt1000, -200~320°C to -200~800°C / (-320~1560°F).
    • T/C: B, E, K, J, N, R, S, T, with CJC.
    • mA: 0~20mA, 0~2.5mA.
    • mV: -25~25mV to -200~200mV.
    • V: 0~1V to 0~15V.
    • Pulse/Digital: Meter pulses, Counting and Frequency. Max speed 2500Hz.
  • Low cost Non-Isolated RTD Pt100/Pt1000 only Inputs also available.
  • Four Dedicated Digital, Isolated, Optocoupler Inputs.
    • State or Count.
    • Max speed 8000Hz.
  • Two Analogue, Isolated, 4~20mA Outputs.
  • Two Digital, Isolated, Relay Outputs.
  • Comms Ports (also note the protocol information listed below):
    • Port 1: Isolated RS422/RS485 or Ethernet TCP/IP (option).
    • Port 2: Isolated RS232/RS485.
    • USB programming port via XU-USB programming key.
  • Embedded protocols, Auto Detecting:
    • MicroScan ASCII,
    • Modbus RTU,
    • Modbus TCP.
  • RS422/RS485 Up to 1200m.
  • Cost Effective Radio Installation.
  • Cost Effective PC or PLC AI Expansion.
  • Clock/Reset Drive up to Four 2100-M input expansion.
  • Selectable Baud Rates.
  • Integral MODBUS Bridge to MicroScan data: 256 analogue (words), and 128 digital (bits).
  • Average comms message, RS232, RS422, RS485, Ethernet = 100msec.
  • 4 messages required to read all inputs.
  • Internal memory refresh rate for all channels = 4 secs.
  • Interface for 2400-R2 (16 & 32 Relay output expansion).
  • Stand-alone memory logging option with 2400-A16-SD.
  • Easy Programming.
  • Programmable Station Number.
  • Programmable Relay States – NO or NC.
  • Comms Failure Time-out Using Relay 2.
  • Comms TXE Delay Programming.
  • Programming Information Retained on Power Down.
  • Universal AC/DC Power Supply (three options to select).
  • Compact 35mm DIN Rail Mounting.
  • Easy to Install.
  • Low Cost.This station has all the friendly features of a monitoring station. The Isolated Universal Analogue Inputs are software programmable using the user friendly MicroScan v5.1 or Station Programmer software. Each input can be configured for any of the following inputs: RTD Pt100/Pt1000, Thermocouple, mA, mV, V & Pulse/Digital. There is a convenient wide choice of spans plus Custom spans can be configured also. The accuracy does not alter when changing spans. The analogue inputs on the 2400-A16 can be expanded up to 76 using the 2100-M Input Multiplexers.All 2400-A16 stations come standard (Default ex factory configuration), with:
  • Ordering Information:
  • Description:
  • All Input Channels Configured to RTD Pt100 0~100°C.
  • 4 Dedicated Digital Inputs.
  • 2 Analogue 4~20mA Outputs.
  • 2 Relay Outputs.
  • RS485 or RS232 on Comms Port 2.
Item Code Description
Series 2400-A16-
Input Channel Options I16- 16 Isolated Universal Input Channels.
I8- 8 Isolated Universal Input Channels.
Custom- Custom mix of Isolated and/or Non-Isolated Input Channels. Please contact Intech.
Comms Options (Port 1) 485- Port 1 Fitted with RS485/RS422 Comms.
NET- Port 1 Fitted with Ethernet TCP/IP Comms.
Power Supply Options H 85~265Vac, 95~370Vdc.
M 24~48Vac, 17~72Vdc.
L 10~30Vdc.

 

Ordering Examples:

2400-A16-I16-485-L 2400-A16 with 16 Isolated Universal Input Channels, RS422/RS485 Comms, 10~30Vdc Power Supply.
2400-A16-I16-NET-H 2400-A16 with 16 Isolated Universal Input Channels, Ethernet TCP/IP Comms, 85~265Vac Power Supply.

 

2400-RS232 Optional 5m RS232 Cable for the 2400-A16 (Comms Port 2).
XU-USB USB Programming Key for programming 2400-A16 using Station Programmer software.

(Same Key as used for programming XU Series transmitters, Z-2400-Sleeper, Z-2400-A2 Series, IN-uP4 and uP4-Din). Note: The 2400-A16 can also be programmed via the Comms Ports using our MicroScan v5.1 software.