2-wire isoleret universal input transmitter til DIN skinne (Intech XU2-X)
Indgang: mA, mV, Volt, potmeter, PT100, PT1000 modstandsfølere samt Termocouple type B, E, J, K, N, R, S, T
Optisk isoleret udgang: 4-20mA liniær med området valgt i opsætningen
Programmeres uden beregning inden afsendelse (se tabel for områder, skrives i notatfelt ved bestilling)
Programmeres alternativt via USB (XU-USB program og kabel købes separat)
Beskyttet mod fejltilslutning
Høj nøjagtighed på 0,1%
DIN skinne monteres
DKK 990,00 ekskl. moms
DKK 1.470,00 ekskl. moms Bundle priser for udvalgte varer
Beskrivelse
- Programmable via USB (requires the XU-USB programming key).
- No power supply or calibration required during programming.
- Input Types:
- RTD Pt100 and Pt1000.
- Thermocouple B, E, J, K, N, R, S, T.
- For RTD and Thermocouple; Output is Linear with Temperature.
- mA, mV and V.
- Potentiometer.
- 32 point curve fitter for mA, mV, V inputs.
- Input to Output Isolation 3750Vac.
- High Accuracy 0.1%.
- Reverse Polarity Protection.
- Heartbeat Status LED.
- Zero Adjust pot.
- Case Temperature range -20°C to +80°C.
- Compact DIN Rail Mount Enclosure.
- Easy to Install.
- Low Cost.
Ordering Information:
XU2 | USB Programmable Universal-Input; 4~20mA Output (Loop Powered) Standard = RTD Pt100, 0~100°C Input; Upscale; 4~20mA Output. |
XU-USB | USB Programming Key Note: the same XU-USB can be used to program any of the XU Series transmitters – just change the included adaptor plug for DIN or In-Head!(Same Key as used for programming 2400-A16, Z-2400-Sleeper, Z-2400-A2 Series, IN-uP4 and uP4-Din). |
Note: The table below shows the USB programmable input types etc for the XU2:
The XU2 can be pre-programmed before dispatch or is easily programmed using the XU-USB programming key and the free XU programming software.
ITEM | CODE | DESCRIPTION | |||
Series | XU2- | Universal Input Transmitter | |||
Type of Input | Pt100- | RTD Pt100 DIN (Options JIS & CN10) | |||
Pt1000- | RTD Pt1000 DIN (Options JIS & CN10) | ||||
Tc __- | Thermocouple Type; B, E, J, K, N, R, S, T | ||||
mA- | mA Input impedence = 10Ω | ||||
mV- | mV Input resistance = 300KΩ | ||||
V- | V Input resistance = 300KΩ | ||||
Pot 1- | Potentiometer Low = 1K~2KΩ | ||||
Pot 2- | Potentiometer High = 5K~1MΩ | ||||
Measuring Range | ______- | State Measuring Range | |||
Output Action on Sensor Fail (for Temperature Input types only) |
US | Upscale | |||
DS | Downscale |
Ordering Examples:
XU2 – Pt100 – 0~100C – DS | XU2; RTD Pt100 DIN 0~100°C Input; Downscale; 4~20mA Output. |
XU2 – Tc K – 0~1200C – US | XU2; Thermocouple Type K 0~1200°C Input; Upscale; 4~20mA Output. |