2-wire In-Head universal input transmitter (Intech XU2HN-X)

> Vare nr.: INXU2HN-X

Indgang: PT100, PT1000 modstandsfølere

Udgang: 4-20mA liniær med temperatur området valgt i opsætningen

Programmeres uden beregning inden afsendelse (se tabel for områder, skrives i notatfelt ved bestilling)

Programmeres alternativt via USB (XU-USB program og kabel købes separat)

Beskyttet mod fejltilslutning

Høj nøjagtighed på 0,1%

DKK 470,00 ekskl. moms

Beskrivelse

  • Programmable via USB (requires the XU-USB programming key).
  • No power supply or calibration required during programming.
  • Temperature Input Types:
    • RTD Pt100 and Pt1000.
    • Thermocouple B, E, J, K, N, R, S, T. (XU2HI only).
    • Output is Linear with Temperature.
  • High Accuracy 0.1%.
  • Compact Industrial Head Mount Enclosure.
  • Reverse Polarity Protection.
  • Easy to Install.
  • Low Cost.

Ordering Information:

XU2HI
(Rev 1)
USB Programmable RTD or Thermocouple Temperature Input.
Standard = RTD Pt100, 0~100°C Input; Upscale; 4~20mA Output (Loop Powered).
Input to Output Isolation 3750Vac.
Case Temperature range -20°C to +85°C.
XU2HN
(Rev 1)
USB Programmable RTD Temperature Input.
Standard = RTD Pt100, 0~100°C Input; Upscale; 4~20mA Output (Loop Powered).
Non-Isolating.
Case Temperature range -20°C to +65°C.
XU-Spring-Kit For vibration areas or where wide ambient temperatures exist on the probe head.
XU-USB USB Programming Key
Note: the same XU-USB can be used to program any of the XU Series transmitters
– just change the included adaptor plug for DIN or In-Head!(Same Key as used for programming 2400-A16Z-2400-SleeperZ-2400-A2 SeriesIN-uP4 and uP4-Din).

Note: The tables below show the USB programmable input types etc for the XU2HI / XU2HN:
The XU2HI / XU2HN can be pre-programmed before dispatch or are easily programmed using the XU-USB programming key and the free XU programming software.

XU2HI Ordering Table:

ITEM CODE DESCRIPTION
Series XU2HI- Head Mount Transmitter Isolated
Type of Input Pt100- RTD Pt100 DIN (Options JIS & CN10)
Pt1000- RTD Pt1000 DIN (Options JIS & CN10)
Tc __- Thermocouple Type; B, E, J, K, N, R, S, T
Measuring Range ______- State Measuring Range
Output Action on Sensor Fail US Upscale
DS Downscale

 

Ordering Examples:

XU2HI – Pt100 – 0~100C – DS XU2HI; RTD Pt100 DIN 0~100°C Input; Downscale; 4~20mA Output.
XU2HI – Tc K – 0~1200C – US XU2HI; Thermocouple Type K 0~1200°C Input; Upscale; 4~20mA Output.

 

XU2HN Ordering Table:

ITEM CODE DESCRIPTION
Series XU2HN- Head Mount Transmitter Non-Isolated
Type of Input Pt100- RTD Pt100 DIN (Options JIS & CN10)
Pt1000- RTD Pt1000 DIN (Options JIS & CN10)
Measuring Range ______- State Measuring Range
Output Action on Sensor Fail
(for Temperature Input types only)
US Upscale
DS Downscale

 

Ordering Examples:

XU2HN – Pt100 – 0~100C – DS XU2HN; RTD Pt100 DIN 0~100°C Input; Downscale; 4~20mA Output.
XU2HN – Pt1000 – 0~50C – US XU2HN; RTD Pt1000 DIN 0~50°C Input; Upscale; 4~20mA Output.